Home / Products / Outdoor Lighting / Road Lighting / CiviTEQ / CiviTEQ Large, Narrow road optic / CQ 48L50-740 NR BP 3550 CL2 M60 GY-S

CiviTEQ / CQ 48L50-740 NR BP 3550 CL2 M60 GY-S

96636225

Data Sheet

A large size LED road lighting lantern with 48 LEDs driven at 500mA with Narrow Road optic. Electronic, fixed output control gear. Class II electrical, IP66, IK08. Housing: die-cast aluminium (EN AC-44300), Light grey 150 sanded textured (close to RAL9006). Enclosure: toughened flat glass. Screws: stainless steel, Ecolubric® treated. Supplied with Ø60mm spigot adaptor which can be fitted for post-top (0°/5°/10° tilt) or side-entry (-20°/-15°/-10°/-5°/0° tilt). BPxyzz: Autonomous bi-power reduction (x: hours before midnight, y: hours after midnight, zz: reduction (%)) Complete with 4000K LED. Surge protection: 10kV single pulse common mode and 8kV multipulse common mode and 6kV multipulse differential mode. If permanent DALI system is connected, 6kV multipulse common and differential mode.

Dimensions: 580 x 230 x 160 mm
Luminaire input power: 72 W
Luminaire luminous flux: 11898 lm
Luminaire efficacy: 165 lm/W
Weight: 8.91 kg
Scx: 0.115 m²

Mode selection
  • Lamp position:STD - standard
  • Light Source:LED
  • Luminaire luminous flux*:11898 lm
  • Luminaire efficacy*:165 lm/W
  • Colour Rendering Index min.:70
  • Ballast:1 x 87500825 LCO 90/200-1050/165 NF C ADV3
  • Correlated colour temperature*:4000 Kelvin
  • Chromaticity tolerance (initial MacAdam):5
  • Rated useful life (B10)*:L90 100000 h at 25 °C
  • Luminaire input power*:72 W Power factor = 0.9
  • Dimming:FO
  • LED
  • CE
  • ENEC11 +
  • ENEC11
  • GLedReP
  • IK08
  • IP66
  • Coastal_C5
  • LLedNr
  • SC2 - Protection Class 2
  • Ta=25

Photometry

Photometric configuration

CalcExpress

Use CalcExpress to quickly carry out quick online calculations of required indoor luminaire numbers for rectangular rooms. Enter the calculation parameters for your solution such as room dimensions, mounting height, height of the useful plane and required level of illuminance, and the site will instantly suggest a solution according to the light output ratio method.

Step 1: Technical data
(lm)
(m)
(m)
(%)
Step 2: Room Data
(m)
(m)
(m)
(m)
(%)
Step 3: Result
(lx)
(%)